The main reasons for calibration are to make sure the reliability of the instrument, that they are often trusted. Annual calibration of test and measurement equipment is suggested by the overwhelming majority of manufacturers and it's going to even be appropriate to hold out more frequent calibration should test results start to fluctuate. However, the processes behind loss of accuracy are often little understood, and that they are influenced by a large array of factors.
Instruments accuracy loses over time
Physical mechanical wear and tear is that the biggest factor affecting instrument accuracy. In terms of test lead sockets, this will take the shape of oxidized connections, contamination from fine particles, and physical wear caused by the constant insertion and removal of test leads. All of these issues can cause the leads to sit loosely in the socket which in turn will prevent the tester from holding its null value and lead to variations in readings.
As far as internal components are concerned, relays and rotary switch assemblies are key. The components of high actuation relays are at risk of burning and contamination which ends up in reading fluctuation whilst impacts sustained during day-to-day use can weaken and damage mechanical relays or small surface mount components which are damaged by larger components banging against them.
The most important factors that influence the accuracy
So many factors influence accuracy from one moment to subsequent that it might be impossible to list them here but environmental conditions are particularly important. Manufacturers define an optimal temperature at which to store testers and, although this is often impossible in practice when instruments are left in extreme conditions - for instance in cold vans overnight - they will read less accurately. There also are specific tests that will affect accuracy. For example, the heat produced by repetitive high current loop testing will condense the air inside the tester which also affects readings. It is therefore a decent idea to understand the instrument’s specification.
Calibration and adjustment
A measurement error is a difference between a measured value of quantity and its true value. Such errors tend to become more frequent the longer equipment is operational. At a while, the deviations could be so great that they're not within the specifications, which suggests that quality is not any longer assured.
By calibrating the device, the measurement error is often determined and documented. If the measurements are outside the permissible range, the device must be adjusted. In this process, the measuring device is reconfigured in order that measurement errors are minimized and deviations from the setpoint value are within the device specifications.
Why should the calibration necessary?
The calibration is recommended in order to see how a unit has drifted from its factory-adjusted settings over the year. In the meantime, it's recommended to use a checkbox so as to verify a unit’s performance, even as a driver checks oil, water, and tire pressure before setting out on a long car journey. Experienced electricians can often spot a suspect reading but there's always a little degree of doubt about whether the tester is reading correctly so a top-quality checkbox constitutes a useful method of reaffirming the testers’ accuracy.
The calibration certificate will show the difference between the worth applied to the unit and therefore the actual reading the tester displays. It is quite uncommon for the unit to read the exact value applied by the calibrator, hence why manufacturers state tolerance for each of the tester’s functions.
The calibration process work
Before commencing calibration, instruments are stored during a temperature-controlled environment in order that the air inside the unit is at an equivalent temperature because of the ambient air. Any visible contamination to sockets and plugs is additionally removed. The tester will then be attached to calibration equipment, preferably using test leads supplied by the end-user. Otherwise, laboratory test leads are going to be used and this may be indicated on the ultimate certificate.
For each of the tester’s functional settings, a series of values are going to be applied to go from an all-time low point to the very best point within the measuring range. Computer software compares the variation within the supplied and displayed values against permitted tolerances and thereby calculates a pass or fail result. Should the unit tend a fail result, it'll be adjusted back to specification consistent with the manufacturer’s procedures and tolerances.
Once the reading for all applied values achieves a pass result and therefore the unit meets the standards taken off within the manufacturer’s specification, a calibration certificate is going to be issued and anti-tamper seals will be fitted to the unit.